An 8-bit dual-supply transceiver with DIR set correctly and data passing still shows the bus occasionally stuck at mid-level with elevated current. The problem is not at the protocol layer but in three overlooked details: the VCCA threshold, the OE# power-up state, and the DIR switching sequence.
The DIR and OE# input thresholds of the ASC8T245S2Y reference VCCA, not a fixed TTL level. With VCCA=1.8V, VIH minimum is 1.35V, which a 1.8V FPGA can recognize; with VCCA=3.3V, VIH minimum is 2.31V, and a 1.8V high level is insufficient; with VCCA=5V, VIH minimum is 3.5V, and even 3.3V is not enough. The satellite payload board case in the source material is exactly VCCA=3.3V paired with a 1.8V FPGA, where DIR was misjudged and the direction occasionally reversed. The correct approach is to place the FPGA on the A side with VCCA set to its I/O bank voltage, and the bus side on the B side. This means the first step for mixed-voltage interfaces is not timing tuning but verifying that the power domains and thresholds match.
The device does not specify break-before-make timing for DIR switching. The conservative sequence is to first pull OE# high to put both ends in high impedance, wait beyond the maximum disable delay of 31.5ns, then switch DIR, and after the direction stabilizes pull OE# low to re-enable; the maximum enable delay is 41.6ns, and the budget should use the maximum value plus margin. If DIR is changed while OE# is active, the original output may conflict with the new driver, appearing on the oscilloscope as a level stuck at mid-rail with elevated current. The device has no short-circuit current limiting or thermal shutdown, so contention is not automatically protected. The real issue is that a software default sequence cannot replace hardware interlocking; a multi-master shared bus requires arbitration or independent chip selects.
With VCCB=5V, the B-side VIH minimum is 3.5V, and 3.3V logic is insufficient; with VCCB=4.5V, VIH minimum is 3.15V, leaving only 150mV of margin. The correct connection is to put the 3.3V device on the A side with VCCA=3.3V and the 5V device on the B side with VCCB=5V, letting the transceiver perform the translation. The output side must also be checked: at 3.0V/24mA, VOH minimum is 2.4V, only 90mV above the 3.3V VIH of 2.31V. The active output tolerance range is 0 to VCCO, with an absolute maximum of VCCO+0.5V; only tri-stated or powered-down I/Os are allowed to reach 5.5V. During power-up, OE# should be externally pulled up to VCCA; DIR has no internal default state and must be externally pulled to a safe level; VCC isolation guarantees high impedance only when either supply is at GND, which does not cover slow ramps or floating supplies.
For engineers in China working on high-speed interfaces and board design, the troubleshooting logic for this device transfers directly to similar dual-supply transceivers: first check whether VCCA and the FPGA I/O are in the same domain, then check the OE# power-up default state, and finally check whether DIR switching is isolated. The device has no bus hold, current limiting, or thermal shutdown, meaning protection must be implemented on the system side; pull-ups/pull-downs must be explicit in the BOM, and software initialization cannot be relied upon. If the project involves spaceborne, hot-swap, or active/standby switching, the connector-side default direction levels and external current limiting need to enter schematic review early; otherwise it may work in the lab but fail at high temperature or after system integration.